No. 30 Merrion Street Upper (D02 Y239) and No. 1 Merrion Place (D02 R129), Dublin 2, Dublin, D02Y239
Data updated 12 Sept 2026 · register lag up to 7 days · sources & freshness
WEB1074/26 is a planning application for permission at No. 30 Merrion Street Upper (D02 Y239) and No. 1 Merrion Place (D02 R129), Dublin 2, Dublin, D02Y239, received by Dublin City Council on 14 Jan 2026 and first seen by Planning Register on 11 Sept 2026. The application describes: PROTECTED STRUCTURE: The development will consist of:- Change of use from commercial offices to reinstate residential use to provide 4 storey own-door residential unit (486sqm) over ancillary basement level storage (80sqm) to be used solely for purposes incidental to the enjoyment of the residential unit as such, each with pedestrian access directly from Merrion Street Upper and with vehicular and rear access via the existing gated car port entrance at No. 1 Merrion Place.- Re-ordering, alteration and refurbishment of the building interiors to facilitate the above change of use / reinstatement of residential accommodation, including restoration of a number of original features, removal of a number of modern interventions and removal of some original fabric; Alteration and refurbishment works include; (i) Removal of the top floor metal fire escape gantry connecting rear of No's 31, 32 ,33 Merrion Street Upper (protected structures RPS Ref Nos. 5225, 5226, 5227) to rear of No.30 Merrion Street Upper at third floor level together with the removal of the metal fire-escape stairs located at No.1 Merrion Place discharging to the rear ground-floor car port. (ii) Demolition of modern second floor office and pitched roof to No.1 Merrion Place and replacement with flat roof, landscaped roof terrace at second floor level together with provision of raised parapet guarding. Internal alterations at first floor level to provide bedroom accommodation.(iii) Removal of later internal low pitched accommodation stairs, to No.30 Merrion Street Upper, between ground and second floor landing and replacement with standard pitch stairs modelled on the original stairs in No.31 Merrion Street Upper together with repair of associated landings and removed tying walls. (iv) Removal of the bulkhead above the main stairs and subsequent reordering/ removal of later toilet and storerooms off landings to facilitate new window to main stairs to rear east return at second floor level and insertion of new structure over. (v) Removal of the rear accommodation stairs within No.1 Merrion Place and reordering of its ground floor entrance to accommodate a new lift core between ground and second floor. Formation of new openings to original layout to 3 storeys return to No. 30 Merrion Street Upper to provide for level access to lift core. (vi) Internal subdivision of rooms to rear return No. 30 Merrion Street Upper to accommodate new bathrooms, kitchen and level access from lift core to rear. (vii) Removal of later sash window and bricking up of original window opening to second floor north elevation of No. 30 Merrion Street Upper.(viii) Repair and repointing of historic brickwork and structural tying to southern gable elevation. Partial repair of front elevation at balconies and conservation repair of front footpath metal railing and granite stallriser at street level.(ix) Insertion of conservation double glazing in existing modern replacement single glazed sash windows and conservation repairs to shutter boxes.(x) Provision of new fire compartmentation, upgrading of doors to fire doors, installation of fire alarm(s) and installation of sprinklers throughout the proposed 4 storey residential unit. (xi) Installation of insulation and screed over the existing non-original concrete basement floor to accommodate under floor heating installation at basement level only. Associated heat pump to be located in rear basement level passage way.(xii) Repairs/renewals of the existing roof to No. 30 Merrion Street Upper and insertion of 1no. new rooflight, replacement of 2no. existing rooflights.(xiii) The existing car port access from Merrion Place is to remain in situ.(xiv) The application includes all associated site and drainage works and services installations. The council granted permission on 10 Mar 2026. The five-week observation window closed on 18 Feb 2026. The site is zoned null under the Dublin City Council development plan. The scheme is for 1 unit. Within 500 m there are 116 other decided applications in the last five years and 45 appeals.
Proposal
PROTECTED STRUCTURE: The development will consist of:- Change of use from commercial offices to reinstate residential use to provide 4 storey own-door residential unit (486sqm) over ancillary basement level storage (80sqm) to be used solely for purposes incidental to the enjoyment of the residential unit as such, each with pedestrian access directly from Merrion Street Upper and with vehicular and rear access via the existing gated car port entrance at No. 1 Merrion Place.- Re-ordering, alteration and refurbishment of the building interiors to facilitate the above change of use / reinstatement of residential accommodation, including restoration of a number of original features, removal of a number of modern interventions and removal of some original fabric; Alteration and refurbishment works include; (i) Removal of the top floor metal fire escape gantry connecting rear of No's 31, 32 ,33 Merrion Street Upper (protected structures RPS Ref Nos. 5225, 5226, 5227) to rear of No.30 Merrion Street Upper at third floor level together with the removal of the metal fire-escape stairs located at No.1 Merrion Place discharging to the rear ground-floor car port. (ii) Demolition of modern second floor office and pitched roof to No.1 Merrion Place and replacement with flat roof, landscaped roof terrace at second floor level together with provision of raised parapet guarding. Internal alterations at first floor level to provide bedroom accommodation.(iii) Removal of later internal low pitched accommodation stairs, to No.30 Merrion Street Upper, between ground and second floor landing and replacement with standard pitch stairs modelled on the original stairs in No.31 Merrion Street Upper together with repair of associated landings and removed tying walls. (iv) Removal of the bulkhead above the main stairs and subsequent reordering/ removal of later toilet and storerooms off landings to facilitate new window to main stairs to rear east return at second floor level and insertion of new structure over. (v) Removal of the rear accommodation stairs within No.1 Merrion Place and reordering of its ground floor entrance to accommodate a new lift core between ground and second floor. Formation of new openings to original layout to 3 storeys return to No. 30 Merrion Street Upper to provide for level access to lift core. (vi) Internal subdivision of rooms to rear return No. 30 Merrion Street Upper to accommodate new bathrooms, kitchen and level access from lift core to rear. (vii) Removal of later sash window and bricking up of original window opening to second floor north elevation of No. 30 Merrion Street Upper.(viii) Repair and repointing of historic brickwork and structural tying to southern gable elevation. Partial repair of front elevation at balconies and conservation repair of front footpath metal railing and granite stallriser at street level.(ix) Insertion of conservation double glazing in existing modern replacement single glazed sash windows and conservation repairs to shutter boxes.(x) Provision of new fire compartmentation, upgrading of doors to fire doors, installation of fire alarm(s) and installation of sprinklers throughout the proposed 4 storey residential unit. (xi) Installation of insulation and screed over the existing non-original concrete basement floor to accommodate under floor heating installation at basement level only. Associated heat pump to be located in rear basement level passage way.(xii) Repairs/renewals of the existing roof to No. 30 Merrion Street Upper and insertion of 1no. new rooflight, replacement of 2no. existing rooflights.(xiii) The existing car port access from Merrion Place is to remain in situ.(xiv) The application includes all associated site and drainage works and services installations.
- Status
- Decision Notice Issued
- Decision
- Grant permission on 10 Mar 2026
- Final grant
- 14 Apr 2026
- Units
- 1
- Site (from polygon)
- 217 m²
- Location precision
- site (coords_polygon)
Timeline
- 14 Jan 2026New applicationObservation window closed 18 Feb 2026
- 10 Mar 2026DecisionAppeal window closed 7 Apr 2026

Full planning report for 53.33924, -6.25209
One document, every dataset, each section with its source and fetch time. Print it or download it as a PDF. It informs a planning search; it is not a statutory search.
1 Where this is — preview
1 Deadlines still open
Appeal
Not appealed.
Commencement
No commencement notice matched to this reference.
Zoning at the site
Zone Z8 - DEV PLAN 2022-2028
Z8: Georgian Conservation Areas: To protect the existing architectural and civic design character, and to allow only for limited expansion consistent with the conservation objective.
Zoned to protect the open land between urban areas. Development is strongly resisted.
Designations within 250 m
No OPW flood extent nearby.
- NIAH-recorded building · 193
- Radon risk area · 1
- Recorded monument · 184
Provenance
Register row from the national planning applications feed (NPAD), fetched 11 Sept 2026, 18:51 (store id 74289). Deadlines were computed by the store from the received / decided dates under the Planning and Development Act 2000 and are recorded as events, not recomputed here.
Source: npad · fetched 11 Sept 2026, 18:51
| Source | Licence | Fetched | Link |
|---|---|---|---|