Carranstown , Caulstown , Platin Duleek County Meath
Data updated 12 Sept 2026 · register lag up to 7 days · sources & freshness
2360212 is a planning application for permission at Carranstown , Caulstown , Platin Duleek County Meath, received by Meath County Council on 11 Aug 2023 and first seen by Planning Register on 11 Sept 2026. The application describes: the proposed development will comprise a 170MW (electrical output) Open Cycle Gas Turbine (OCGT) Power Plant. The proposed development will comprise an electricity generating plant which will use Hydrotreated Vegetable Oil (HVO) as fuel and will be connected to a previously consented 110kV substation (ABP-303678-19) and associated site works and improved access from the R152. The development comprises the following elements: a) Three gas turbine buildings (each 990m2) each housing 1 no. turbine, 1 no. generator and auxiliary equipment with a total of 269 MWth (thermal output) generating capacity all on concrete plinths. b) The power plant will have three exhaust stacks (25m in height), one exhaust stack per OCGT. Therefore, each OCGT will comprise a standalone Large Combustion Plant. The power plant may need to utilise, selective catalytic reduction (SCR) (18m high, 4.5 width, 14m length) for nitrogen oxides abatement. c) Water treatment plant comprising: • a 275m2 Deionising Building (6m high x 11m wide x 25m long) • a raw water treatment tank of 2,262m3 ( 12.8m high) • a deionised water tank (max. volume of 3,925m3). 15.4m high • a processed water tank of 450m3 (9m high) • 1 no. 20m2 firefighting water tank of 45m3 (2m high) • 1 no. 25m2 firewater module (4m high x 5m wide x 5m long) • 1 no. 41m2 sanitary foul water cesspool tank of 79m3 located underground (1.98m high x 2.5m wide x 16m long) • a bulk chemical storage area (4.75m wide x 7.75m long) d) 2 no. HVO tank (max. storage of 2300 m3 of HVO per tank), 13m high with a diameter of 15m and associated fuel pumping and filtering equipment and pipework, within a 43.5m L x 45.5m W x 1.5m Bund capacity is 2970m3. e) 1 ammonia tank –1.8m high x 3.5m length with bund 2.5 m x 5 m with a height of 1.5 m. f) 1 no. fuel polishing system (3m high x 6m wide x 24m long). g) 2 no. 110 kV transformers each 160m2, and each measuring (5m high x 10m wide x 15m long). 3 no. Lightning Masts (18m in height) and kiosks,cable gantry connection to the adjoining consented 110 kV Substation. h) A 520m2 services building (6m high x 13m wide x 40m long). i) A 160m2 Switchgear (MV) building (5m high x 6.1m wide x 26.3m long). j) All other miscellaneous and ancillary site works, including: 12 no. Car parking spaces and 1 No. fuel unloading bay, one lowered site platform area, new internal roads and hard and soft landscaping including material berms (1.2m to 2m high), a temporary construction compound, temporary. The council granted permission on 15 Feb 2024, with conditions. The five-week observation window closed on 15 Sept 2023. The register records an appeal (ABP-319278-24), decided: modified. Within 500 m there are 3 other decided applications in the last five years.
Proposal
the proposed development will comprise a 170MW (electrical output) Open Cycle Gas Turbine (OCGT) Power Plant. The proposed development will comprise an electricity generating plant which will use Hydrotreated Vegetable Oil (HVO) as fuel and will be connected to a previously consented 110kV substation (ABP-303678-19) and associated site works and improved access from the R152. The development comprises the following elements: a) Three gas turbine buildings (each 990m2) each housing 1 no. turbine, 1 no. generator and auxiliary equipment with a total of 269 MWth (thermal output) generating capacity all on concrete plinths. b) The power plant will have three exhaust stacks (25m in height), one exhaust stack per OCGT. Therefore, each OCGT will comprise a standalone Large Combustion Plant. The power plant may need to utilise, selective catalytic reduction (SCR) (18m high, 4.5 width, 14m length) for nitrogen oxides abatement. c) Water treatment plant comprising: • a 275m2 Deionising Building (6m high x 11m wide x 25m long) • a raw water treatment tank of 2,262m3 ( 12.8m high) • a deionised water tank (max. volume of 3,925m3). 15.4m high • a processed water tank of 450m3 (9m high) • 1 no. 20m2 firefighting water tank of 45m3 (2m high) • 1 no. 25m2 firewater module (4m high x 5m wide x 5m long) • 1 no. 41m2 sanitary foul water cesspool tank of 79m3 located underground (1.98m high x 2.5m wide x 16m long) • a bulk chemical storage area (4.75m wide x 7.75m long) d) 2 no. HVO tank (max. storage of 2300 m3 of HVO per tank), 13m high with a diameter of 15m and associated fuel pumping and filtering equipment and pipework, within a 43.5m L x 45.5m W x 1.5m Bund capacity is 2970m3. e) 1 ammonia tank –1.8m high x 3.5m length with bund 2.5 m x 5 m with a height of 1.5 m. f) 1 no. fuel polishing system (3m high x 6m wide x 24m long). g) 2 no. 110 kV transformers each 160m2, and each measuring (5m high x 10m wide x 15m long). 3 no. Lightning Masts (18m in height) and kiosks,cable gantry connection to the adjoining consented 110 kV Substation. h) A 520m2 services building (6m high x 13m wide x 40m long). i) A 160m2 Switchgear (MV) building (5m high x 6.1m wide x 26.3m long). j) All other miscellaneous and ancillary site works, including: 12 no. Car parking spaces and 1 No. fuel unloading bay, one lowered site platform area, new internal roads and hard and soft landscaping including material berms (1.2m to 2m high), a temporary construction compound, temporary
- Status
- APPLICATION FINALISED
- Decision
- Conditional on 15 Feb 2024
- Permission expires
- 20 Jan 2035
- Site (from polygon)
- 10.66 ha
- Location precision
- site (coords_polygon)
Timeline
- 11 Aug 2023New applicationObservation window closed 15 Sept 2023
- 4 Oct 2023Further information requested
- 22 Nov 2023Further information received
- 15 Feb 2024DecisionAppeal window closed 14 Mar 2024
- 13 Mar 2024Appeal lodged

Full planning report for 53.67552, -6.38578
One document, every dataset, each section with its source and fetch time. Print it or download it as a PDF. It informs a planning search; it is not a statutory search.
1 Where this is — preview
1 Deadlines still open
Appeal
The register records appeal ABP-319278-24 (status unknown) but we have not matched the ACP case yet.
Commencement
No commencement notice matched to this reference.
Zoning at the site
No zoning objective covers this site in the current plan.
Designations within 250 m
No OPW flood extent nearby.
- Radon risk area · 2
Provenance
Register row from the national planning applications feed (NPAD), fetched 11 Sept 2026, 18:51 (store id 143253). Deadlines were computed by the store from the received / decided dates under the Planning and Development Act 2000 and are recorded as events, not recomputed here. Council register: http://www.eplanning.ie/MeathCC/AppFileRefDetails/2360212/0.
Source: npad · fetched 11 Sept 2026, 18:51
| Source | Licence | Fetched | Link |
|---|---|---|---|
| npad | CC-BY-4.0 | 11 Sept 2026, 18:51 | open |