Derryville , Moyne , Thurles
- 4 Sept 2018Received
- 9 Oct 2018Observations closed
- Status
- Withdrawn or invalid
- Decision
- Not yet
- Council
- Tipperary County Council
- Type
- PERMISSION
- Site
- 78 m²
What’s proposed
installation of a glass lined steel digestate storage tank of 46.1m in diameter and 5.67m in height; an office building of 5.83m in height, 7.6m in width and 15m in length; a hardstanding car parking area comprising 7 no car parking spaces. Retention Permission of existing onsite weighbridge; the existing office portacabin structure of 9m in length, 3m in width and 2.6m in height until 31/12/2019; the existing control room of 4.31m in height, 5.1m in width and 5.06m in length; the biofilter unit & associated pipework installed in its existing orientation; the existing pump house of 2.4m in height, 2.5m in length and 1.5m in width; the existing storage shed of 2.8m in height, 2.5m in length and 1.7m in width; the plant room of 4.82m in height; 7.66m in width, 7.9m, in length & associated ancillary infrastructure including underground holding tank of 45m3 capacity; tank bund area of 10.5m in length and 3m in width
18601078 is a planning application to Tipperary County Council for installation of a glass lined steel digestate storage tank of 46.1m in diameter and, received on 4 Sept 2018; the file is recorded as withdrawn.
Planning details
- Reference
- 18601078
- Local authority
- Tipperary County Council
- Status
- Withdrawn or invalid · register status “WITHDRAWN”
- Received
- 4 Sept 2018
- Observations close
- 9 Oct 2018 (closed 2910 days ago)
- Decision due
- No due date published
- Decision
- Not decided
- Proposed development
- installation of a glass lined steel digestate storage tank of 46.1m in diameter and 5.67m in height; an office building of 5.83m in height, 7.6m in width and 15m in length; a hardstanding car parking area comprising 7 no car parking spaces. Retention Permission of existing onsite weighbridge; the existing office portacabin structure of 9m in length, 3m in width and 2.6m in height until 31/12/2019; the existing control room of 4.31m in height, 5.1m in width and 5.06m in length; the biofilter unit & associated pipework installed in its existing orientation; the existing pump house of 2.4m in height, 2.5m in length and 1.5m in width; the existing storage shed of 2.8m in height, 2.5m in length and 1.7m in width; the plant room of 4.82m in height; 7.66m in width, 7.9m, in length & associated ancillary infrastructure including underground holding tank of 45m3 capacity; tank bund area of 10.5m in length and 3m in widthAs published by the register.
- Site area
- 78 m² from the mapped boundary, not the council's figure
- Applicant
- Not published — the national feed carries no applicant name council register
Nearby 1 application within 500 m in the last 5 years
Appeal
Not appealed.
Commencement
No commencement notice matched to this reference.
Zoning at the site
No zoning objective covers this site in the current plan.
Designations within 250 m
No OPW flood extent nearby.
No other designation nearby.
Provenance
Register row from the national planning applications feed (NPAD), fetched 18 Sept 2026, 15:44 (store id 463291). Deadlines were computed by the store from the received / decided dates under the Planning and Development Act 2000 and are recorded as events, not recomputed here. Council register: http://www.eplanning.ie/TipperaryCC/AppFileRefDetails/18601078/0.
Source: npad · fetched 18 Sept 2026, 15:44
| Source | Licence | Fetched | Link |
|---|---|---|---|
| npad | CC-BY-4.0 | 18 Sept 2026, 15:44 | open |