16 Herbert Street, Dublin 2
- 21 Aug 2023Received
- 11 Oct 2023Refuse permission
- 7 Nov 2023Appealed
- 1 Aug 2024Appeal: Granted with conditions
- 1 Aug 2024Final grant
- 16 Dec 2025Commenced
- Status
- Commenced
- Decision
- Refuse permission · 11 Oct 2023
- Council
- Dublin City Council
- Type
- Permission
- Units
- 11
- Site
- 209 m²
- Appeal
- ACP 318409 · Granted with conditions
What’s proposed
PROTECTED STRUCTURE: the development will consist of a change of use from office to residential and comprise the sub-division of residential units, including 2 x 1 bed units (measuring 47 sq.m. and 52 sq.m.) and 9 studio units with an average area of 29 sq.m. The proposed works extend to an overall site area of circa. 210 sq.m. and shall comprise the following: (1) removal of non-original elements to the rear. This includes (i) the modern L-shaped basement structure at basement level; (ii) the modern plan room structure at ground floor level and brick flue enclosure to above eaves level; (iii) the modern steel deck which extends across the rear facade of no. 16 at first, second and third floor level; (iv) the toilet block constructed on the roof of the oroginal 2-storey return structure; (v) the 2 no. projecting bay windows to the north and east elevations of the original 2-storey return; (vi) the single storey flat roofed modern extension to the rear at the former garden level; (2) new construction works to the former garden level, comprising a new 40 sq. single storey structure at basement level with a green roof (to provide a 1 bed apartment unit) to replace a non-original 50 sq.m. office structure constructed at ground floor level; (3) new construction works to the original 2-storey return at the rear, comprising a 3.6 sq.m. semi-circular extension to the original gable to include a new stair, the reinstatement of the original mansard type roof structure (following the removal of the modern toilet block) and new window opening to the north facade, (4) general external upgrade works and construction repairs to the building envelope to include (i) replacing the finishes to the historic double pitch roof and valley gutter, (ii) installing a new automatic openable roof vent over the stair, (iii) replacement of existing front UPVC rainwater goods to the front elevation; (iv)replacement of the non-original external steel access stair to front lightwell; (v) cleaning of all original brickwork; (vi) repair of the original windows; (vii) new services/plant to replace existing in the existing cellar / front lightwell; (5) various internal upgrade works and conservation repairs; incorporating works required to achieve compliance with current building regulations, including : (i) removing the non-original lift; (ii) removing the non-original steel stair from ground floor level to basement, (iii) damp proofing works to the basement; (iv) internal dry lining works to the basement; (v) upgrade of existing timber floors to meet fire and acoustic performance requirements; (vi) new concrete floor construction to the basement; vii) new electrical and mechanical services installations to serve the residential units; (viii) historic plasterwork repairs
4340/23 is a planning application to Dublin City Council for pROTECTED STRUCTURE: the development will consist of a change of use from office to, received on 21 Aug 2023; permission was refused on 11 Oct 2023.
Planning details
- Reference
- 4340/23
- Local authority
- Dublin City Council
- Status
- Commenced · register status “Appeal Decided”
- Received
- 21 Aug 2023
- Observations close
- 25 Sept 2023 (closed 1089 days ago)
- Decision due
- 13 Oct 2023 · decided 11 Oct 2023
- Decision
- Refuse permission on 11 Oct 2023
- Proposed development
- PROTECTED STRUCTURE: the development will consist of a change of use from office to residential and comprise the sub-division of residential units, including 2 x 1 bed units (measuring 47 sq.m. and 52 sq.m.) and 9 studio units with an average area of 29 sq.m. The proposed works extend to an overall site area of circa. 210 sq.m. and shall comprise the following: (1) removal of non-original elements to the rear. This includes (i) the modern L-shaped basement structure at basement level; (ii) the modern plan room structure at ground floor level and brick flue enclosure to above eaves level; (iii) the modern steel deck which extends across the rear facade of no. 16 at first, second and third floor level; (iv) the toilet block constructed on the roof of the oroginal 2-storey return structure; (v) the 2 no. projecting bay windows to the north and east elevations of the original 2-storey return; (vi) the single storey flat roofed modern extension to the rear at the former garden level; (2) new construction works to the former garden level, comprising a new 40 sq. single storey structure at basement level with a green roof (to provide a 1 bed apartment unit) to replace a non-original 50 sq.m. office structure constructed at ground floor level; (3) new construction works to the original 2-storey return at the rear, comprising a 3.6 sq.m. semi-circular extension to the original gable to include a new stair, the reinstatement of the original mansard type roof structure (following the removal of the modern toilet block) and new window opening to the north facade, (4) general external upgrade works and construction repairs to the building envelope to include (i) replacing the finishes to the historic double pitch roof and valley gutter, (ii) installing a new automatic openable roof vent over the stair, (iii) replacement of existing front UPVC rainwater goods to the front elevation; (iv)replacement of the non-original external steel access stair to front lightwell; (v) cleaning of all original brickwork; (vi) repair of the original windows; (vii) new services/plant to replace existing in the existing cellar / front lightwell; (5) various internal upgrade works and conservation repairs; incorporating works required to achieve compliance with current building regulations, including : (i) removing the non-original lift; (ii) removing the non-original steel stair from ground floor level to basement, (iii) damp proofing works to the basement; (iv) internal dry lining works to the basement; (v) upgrade of existing timber floors to meet fire and acoustic performance requirements; (vi) new concrete floor construction to the basement; vii) new electrical and mechanical services installations to serve the residential units; (viii) historic plasterwork repairsAs published by the register.
- Site area
- 209 m² from the mapped boundary, not the council's figure
- Applicant
- Not published — the national feed carries no applicant name
Full planning report for 53.33580, -6.24496
Zoning, appeals, sold prices, flood and heritage — the whole area in one PDF.
No account, no payment. Not a statutory planning search.
Appeal
Commencement
- Seven day notice SN0013493DC
Zoning at the site
Zone Z8 - DEV PLAN 2022-2028
Z8: Georgian Conservation Areas: To protect the existing architectural and civic design character, and to allow only for limited expansion consistent with the conservation objective.
Zoned to protect the open land between urban areas. Development is strongly resisted.
Designations within 250 m
No OPW flood extent nearby.
- Natural Heritage Area (incl. proposed) · 1
- NIAH-recorded building · 170
- Radon risk area · 1
Provenance
Register row from the national planning applications feed (NPAD), fetched 11 Sept 2026, 18:51 (store id 70753). Deadlines were computed by the store from the received / decided dates under the Planning and Development Act 2000 and are recorded as events, not recomputed here.
Source: npad · fetched 11 Sept 2026, 18:51
| Source | Licence | Fetched | Link |
|---|---|---|---|
| npad | CC-BY-4.0 | 11 Sept 2026, 18:51 | open |